Technical Data - Notes
Type of gas:
Natural Gas I2H
Natural Gas II2H3+*
LP Gas I3+
Please see data badge your for specified gas
type. * Can be converted from Natural gas to LP Gas
Never attempt to convert an appliance
- unless the data badge states that you
can.
Burner Aeration:
Fixed
Pressure setting:
G20 Natural Gas @ 20mbar
G30 Butane @ 28-30mbar
G31 Propane @ 37mbar
Electrical supply:
220 - 240V ~ 50Hz
Injectors used (hotplate)
Countries of destination:


Size Natural
Gas
LP gas
Small 77 50
Medium 104 70
Large 129 87
Wok 121 & 63 87 & 35